Common array manager.

Sun Storage 2530-M2 Array - Version Not Applicable and later: Sun StorageTek[TM] Common Array Manager Software: Enabling Automatic Service Request Generation ... is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Critical alarms generate a …

Common array manager. Things To Know About Common array manager.

The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is … Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ... The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …

vi Sun StorageTek Common Array Manager ユーザーズガイドオープンシステム用• 2010 年 2 月 FMS エージェントの構成 65 アレイの健全性の監視の有効化 67 アラームとイベントの監視 67 アラーム情報の表示 68 アラームの管理 70 アラームの承認 70 1 つまたは複数のアラーム ...

The Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.The purpose of this document is to describe how to collect logs and configuration data from the machine running Sun Storage Common Array Manager version 6.0 or later. The command will collect the configuration database and all relevant log files for support and troubleshooting. If you need to collect a support data from the array, please …

This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Array Technologies (NASDAQ: ARRY) has surpassed Wall Street projections four times, including the last quarterly EPS of 21 cents per share, 91% higher …Mar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in …

Chapter 1 Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle's Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0 product release.

Sun Storage 2530-M2 Array - Version Not Applicable and later: Sun StorageTek[TM] Common Array Manager Software: Enabling Automatic Service Request Generation ... is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Critical alarms generate a …

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Dell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests.1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage 2530-M2 Array - Version Not Applicable and later Information in this document applies to any platform. Goal. Sun Storage 2500, 2500-M2, and 6000 arrays support Dynamic Volume Expansion (DVE). DVE is an operation that allows the user-visible …

Sun Storage Common Array Manager Installation and Setup Guide Administration, configuration, and monitoring Online help integrated with the software. Customer and field replacement procedures Service Advisor integrated with the software. Reference information for the CLI Sun Storage Common Array Manager CLI Guide sscsman pagesApplying Solaris patch 147416-02 (sparc) or patch 147419-02 (x86) to Sun Storage Common Array Manager (CAM) version 6.9.0 may cause registered arrays to present an alarm stating that out-of-band (oob) communication has been lost, and report the health status of the array as "Lost Communication"——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ... Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).

Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1vi Sun StorageTek Common Array Manager Software Installation Guide • October 2006 Creating Initiators to Assign to Hosts 61 To Create An Initiator and Assign It To a Host: 61 Using the New Volume Wizard to Create and Map Volumes 62 To Use the New Volume Wizard to Create Volumes 62 About Volumes and the Default Domain or Partitioned …

Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ...Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …Storage Common Array Manager 6.10 Update. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 …SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details …Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1 Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

The Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …

Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux ForumsCategory filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.iv Sun StorageTek Common Array Manager CLI Guide • April 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 29 Examples 30Support data for an array is collected and saved in the Common Array Manager by selecting array > General Configuration > Support Data. On the Windows 2008 server, disable “Do not save encrypted pages to disk.” Go to Tools > Internet Options > Advanced > Security and uncheck "Do not save encrypted pages to disk." Linux platformsOn the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x 3.This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support …Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common …

Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM.Sun Storage Common Array Manager Software 6.7.0 Release Notes: PDF: Sun Storage Array Baseline Firmware: PDF: Sun Storage Common Array Manager Array Administration Guide, Version 6.7.0: PDF: Sun Storage Common Array Manager Quick Start Guide: PDF: Sun Storage Common Array Manager Installation and Setup Guide: …Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.10 [Release 6.0] Information in this document applies to any platform. Symptoms. When attempting to launch Service Advisor from Sun Storage Common Array Manager (CAM), the following message appears: "Service advisor package not installed for this type of device."Instagram:https://instagram. onlinetvswordigoprivate no callflights from san diego to seattle Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 … studyable.apphow to unblock blocked websites Mar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices lock and alert Multiple array management<br /> Remote Proxy<br /> The remote proxy agent enables communication, equivalent to in-band management,<br /> from the full management host to the array over an out-of-band-band IP network.<br />This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Overview. Sun StorageTek (TM) Common Array Manager is a Shareware software in the category Desktop developed by Sun StorageTek (TM) Common Array Manager. The latest version of Sun StorageTek (TM) Common Array Manager is currently unknown. It was initially added to our database on 10/30/2007.